1. In high‑speed applications, if measured temperature rise exceeds 70°C, switch to a machined cage.2. Temperature: material property vs. temperature curves are openly available.3. Hand‑rotating noise: “clicking” sounds indicate pocket wear – shorten relubrication intervals.4. Inspection: red wear debris on cage surface indicates insufficient lubrication or deformation.