· In high‑speed applications, if measured temperature rise exceeds 70°C, switch to a machined cage.· Temperature: material property vs. temperature curves are openly available.· Hand‑rotating noise: “clicking” sounds indicate pocket wear – shorten relubrication intervals.· Inspection: red wear debris on cage surface indicates insufficient lubrication or deformation.